Thoracic Research and Practice
Original Article

The Efficacy of Flutter® and Active Cycle of Breathing Techniques in Patients with Bronchiectasis: A Prospective, Randomized, Comparative Study

1.

Clinic of Occupational Diseases, Atatürk Chest Diseases and Thoracic Surgery Training and Research Hospital, Ankara, Turkey

2.

Department of Chest Diseases, Trakya University School of Medicine, Edirne, Turkey

3.

Chest Diseases Service, Hatay Dörtyol State Hospital, Hatay, Turkey

4.

Department of Physical Therapy and Rehabilitation, Trakya University School of Medicine, Edirne, Turkey

5.

Department of Biostatistics and Medical Informatics, Trakya University School of Medicine, Edirne, Turkey

Thorac Res Pract 2018; 19: 103-109
DOI: 10.5152/TurkThoracJ.2018.17050
Read: 3516 Downloads: 1140 Published: 18 July 2019

Abstract

OBJECTIVES: The objective of the study was to compare the efficacy of an oscillating positive expiratory device and the active cycle of breathing techniques (ACBT) in patients with bronchiectasis.


MATERIALS AND METHODS
: A home-based study that lasted for 4 weeks was designed to compare the oscillating physiotherapy device Flutter® and the ACBT in 40 patients, who were randomly assigned into two groups containing 20 patients each. The effect of the two methods of physiotherapy on sputum production, pulmonary functions, and the quality of life was compared.


RESULTS
: The results of the present study indicate that both the methods were associated with a reduced number of patients complaining of cough and fatigue and increased sputum production (p=0.000, p=0.004, and p=0.002, respectively). In addition, statistically significant reductions were determined by the Medical Research Council and Borg Dyspnea scores (p=0.001 and 0.002, respectively). The Flutter® device caused a more significant effect on the perception of dyspnea. Overall, there was an improvement in the physical sub-scale of the Short Form (SF)-36 Quality of Life Questionnaire scores of 36 patients who completed the study (p=0.001). During the physiotherapy period, no changes in pulmonary functions were observed. Exacerbations were recorded in 3 patients in the ACBT group and in 1 patient in the Flutter® group.


CONCLUSION
: The Flutter® device and ACBT represent effective home-based physiotherapeutic methods. The Flutter® device appears to be more effective with regard to sputum production.
 

Cite this article as: Üzmezoğlu B, Altıay G, Özdemir L, et al. The Efficacy of Flutter® and Active Cycle of Breathing Techniques in Patients with Bronchiectasis: A Prospective, Randomized, Comparative Study. Turk Thorac J 2018; 19(3): 103-9.

Files
EISSN 2979-9139