Application of Fibrin Sealant (Tisseel) Via Bronchoscopy in the Management of a Postlobectomy Bronchopleural Fistula

1. Başkent University Hospital, Departments of Anesthesiology, Ankara, Turkey
2. Başkent University Hospital, Departments of Thoracic Surgery, Ankara, Turkey
No information available.
No information available
Accepted Date: 07.10.2021
Online Date: 07.10.2021
Publish Date: 07.10.2021
PDF
Cite
Share
Request

Abstract

Bronchopleural fistula (BPF) is the most serious postoperative complication of thoracic surgery. We report a patient with non-small-cell lung cancer (NSCLC) who developed BPF after undergoing lobectomy. To close the fistula, we instilled fibrin sealant (Tisseel) in the bronchial stump via a fiberoptic bron­choscope using a balloon catheter. We discuss the technique and our results obtained with this method.